Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 101
Filter
1.
Bioanalysis ; 15(10): 581-589, 2023 May.
Article in English | MEDLINE | ID: covidwho-20239009

ABSTRACT

Aims: This study was designed to analyze the requirements for clinical trials of SARS-CoV-2 antigen testing to explore the rationality and scientific rigor of clinical trials. Methods: The guidelines for the listing of SARS-CoV-2 antigen tests were compared and the requirements for clinical trials were analyzed to find similarities and differences between China, the USA and Europe. Results: The requirements for clinical trials of SARS-CoV-2 antigen tests in China, the USA and Europe were consistent in terms of methods. However, differences were found in the requirements for protocol design. Conclusion: The differences in clinical trial requirements stem from regulations and the actual conditions across regions, but all clinical trials are designed to obtain valid clinical performance of products.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , China , Clinical Trials as Topic , COVID-19/diagnosis , Europe , Immunologic Tests , United States
2.
J Clin Virol ; 165: 105495, 2023 08.
Article in English | MEDLINE | ID: covidwho-2327692

ABSTRACT

BACKGROUNDS: Due to immaturity of their immune system, passive maternal immunization is essential for newborns during their first months of life. Therefore, in the current context of intense circulation of SARS-CoV-2, identifying factors influencing the transfer ratio (TR) of neutralizing antibodies against SARS-CoV-2 (NAb) appears important. METHODS: Our study nested in the COVIPREG cohort (NCT04355234), included mothers who had a SARS-CoV-2 PCR positive during their pregnancy and their newborns. Maternal and neonatal NAb levels were measured with the automated iFlash system. RESULTS: For the 173 mother-infant pairs included in our study, the median gestational age (GA) at delivery was 39.4 weeks of gestation (WG), and 29.7 WG at maternal SARS-CoV-2 infection. Using a multivariate logistic model, having a NAb TR above 1 was positively associated with a longer delay from maternal positive SARS-CoV-2 PCR to delivery (aOR 1.09, 95% CI: 1.03 - 1.17) and with a later GA at delivery (aOR = 1.58, 95% CI: 1.09 - 2.52). It was negatively associated with being a male newborn (aOR 0.21, 95% CI: 0.07 - 0.59). In 3rd trimester SARS-CoV-2 infected mothers, NAb TR was inferior to VZV, toxoplasmosis, CMV, measle and rubella's TR. However, in 1st or 2nd trimester infected mothers, only measle TR was different from NAb TR. CONCLUSION: Male newborn of mothers infected by SARS-CoV-2 during their pregnancy appear to have less protection against SARS-CoV-2 in their first months of life than female newborns. Measle TR was superior to NAb TR even in case of 1st or 2nd trimester maternal SARS-CoV-2 infection. Future studies are needed to investigate possible differences in transmission of NAb following infection vs vaccination and its impact on TR.


Subject(s)
COVID-19 , Measles , Pregnancy Complications, Infectious , Infant, Newborn , Pregnancy , Humans , Female , Male , Infant , SARS-CoV-2 , Immunologic Tests , Antibodies, Viral , Antibodies, Neutralizing
3.
J Infect Chemother ; 29(8): 825-828, 2023 Aug.
Article in English | MEDLINE | ID: covidwho-2317792

ABSTRACT

The promising diagnostic performance of rapid antigen tests (RATs) using non-invasive anterior nasal (AN) swab specimens to diagnose COVID-19 has been reported. A large number of RATs are commercially available; however, the careful assessment of RATs is essential prior to their implementation in clinical practice. We evaluated the clinical performance of the GLINE-2019-nCoV Ag Kit as a RAT using AN swabs in a prospective, blinded study. Adult patients who visited outpatient departments and received SARS-CoV-2 tests between August 16 and September 8, 2022, were eligible for this study. Patients who were aged under 18 years and patients without appropriate specimens were excluded. Two sets of AN and nasopharyngeal (NP) swabs were collected from all patients. Each set of specimens was tested by the RAT and quantitative reverse-transcription polymerase chain reaction (RT-qPCR). Of the 138 recruited patients, 84 were positive and 54 were negative by RT-qPCR using NP swabs. The positive agreement rate between RT-qPCR using NP swabs and RAT using AN swabs was 78.6% (95% confidence interval [CI], 68.3%-86.8%), the negative agreement rate was 98.1% (95% CI, 90.1%-99.9%), and the overall agreement rate was 86.2% (95% CI, 79.3%-91.5%), with a κ coefficient of 0.73. The positive agreement rate in the early phase (≤3 days from symptom onset) was >80%, but this fell to 50% in the late phase (≥4 days). This study demonstrates that the GLINE-2019-nCoV Ag Kit using AN swabs has good clinical performance and might be a reliable alternative method for diagnosing COVID-19.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Nasal Cavity , Prospective Studies , Immunologic Tests , Nasopharynx , Sensitivity and Specificity
4.
Clin Lab ; 69(3)2023 Mar 01.
Article in English | MEDLINE | ID: covidwho-2268266

ABSTRACT

BACKGROUND: The diagnostic standard for COVID-19 infection is real-time reverse transcription-polymerase chain reaction (rRT-PCR) of nasopharyngeal swab and oropharyngeal swab specimens. Rapid antigen tests are cheaper and easier to use than the rRT-PCR method. Although the COVID-19 pandemic is settling down, seasonal epi¬demic is expected. In this study, the performance of two rapid antigen test kits was evaluated based on rRT-PCR test results. METHODS: A total of 346 residual samples was tested by the PowerChek SARS-CoV-2 Real-time PCR Kit or STAN-DARD M nCoV Real-Time-Detection kit, STANDARD Q COVID-19 Ag test kit (SQ RAT), and ND COVID-19 Ag test kit (ND RAT). RESULTS: Compared to rRT-PCR as the standard method, the SQ RAT test kit yielded 77.1% sensitivity (101/131) and 100% specificity (215/215), and the ND RAT yielded 89.3% sensitivity (117/131) and 100% specificity (215/ 215). Both RATs showed sensitivity greater than 85% in samples with RdRp gene Ct value less than 25. There was a false-negative case suspected of prozone phenomenon. CONCLUSIONS: Both RATs showed significant performance, but users should beware of the prozone phenomenon.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Pandemics , Immunologic Tests , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity
5.
Sci Rep ; 13(1): 3679, 2023 03 05.
Article in English | MEDLINE | ID: covidwho-2276581

ABSTRACT

Rapid antigen diagnostic (RAD) tests have been developed for the identification of the SARS-CoV-2 infection. However, they require nasopharyngeal or nasal swab, which is invasive, uncomfortable, and aerosolising. The use of saliva test was also proposed but has not yet been validated. Trained dogs may efficiently smell the presence of SARS-CoV-2 in biological samples of infected people, but further validation is needed both in laboratory and in field. The present study aimed to (1) assess and validate the stability over a specific time period of COVID-19 detection in humans' armpit sweat by trained dogs thanks to a double-blind laboratory test-retest design, and (2) assess this ability when sniffing people directly. Dogs were not trained to discriminate against other infections. For all dogs (n. 3), the laboratory test on 360 samples yielded 93% sensitivity and 99% specificity, an 88% agreement with the Rt-PCR, and a moderate to strong test-retest correlation. When sniffing people directly (n. 97), dogs' (n. 5) overall sensitivity (89%) and specificity (95%) were significantly above chance level. An almost perfect agreement with RAD results was found (kappa 0.83, SE 0.05, p = 0.001). Therefore, sniffer dogs met appropriate criteria (e.g., repeatability) and WHO's target product profiles for COVID-19 diagnostics and produced very promising results in laboratory and field settings, respectively. These findings support the idea that biodetection dogs could help reduce the spread of the virus in high-risk environments, including airports, schools, and public transport.


Subject(s)
COVID-19 , Humans , Animals , Dogs , SARS-CoV-2 , Working Dogs , Immunologic Tests , Airports
6.
Clin Chem Lab Med ; 61(8): 1506-1510, 2023 Jul 26.
Article in English | MEDLINE | ID: covidwho-2276490

ABSTRACT

OBJECTIVES: Given that SARS-CoV-2 antigen tests will represent a pillar for supporting or surrogating molecular testing in the endemic period, we report here the clinical performance of the new SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA SARS-CoV-2 Ag). METHODS: The study population consisted of 181 subjects (mean age 61 ± 21 years; 92 females) undergoing coronavirus disease 2019 (COVID-19) testing at the local diagnostic facility, from December 2022 to February 2023. Routine diagnostic practice involved the collection of a double nostril nasopharyngeal swab, analyzed in duplicate with SARS-CoV-2 antigen (MAG-CLIA SARS-CoV-2 Ag) and molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) tests. RESULTS: A significant Spearman's correlation was found between MAG-CLIA SARS-CoV-2 Ag and mean Ct values of SARS-CoV-2 E and S genes (r=-0.95; p<0.001). In all nasopharyngeal samples, the area under the curve (AUC) of MAG-CLIA SARS-CoV-2 Ag was 0.86 (95% CI, 0.81-0.90), with 0.71 sensitivity and 1.00 specificity at 7 ng/L cut-off, increasing to 0.98 (95% CI, 0.96-1.00) AUC and 0.96 sensitivity (with 0.97 specificity) in high viral load samples. When SARS-CoV-2 N protein concentration was replaced with raw instrumental readings (i.e., relative light units [RLU]), the AUC in all samples increased to 0.94. A RLU value of 945 was associated with 88.4% accuracy, 0.85 sensitivity, 0.95 specificity, 0.77 negative predictive value (NPV) and 0.97 positive predictive value (PPV), respectively. CONCLUSIONS: We found satisfactory analytical performance of MAG-CLIA SARS-CoV-2 Ag, which could be used as surrogate of molecular testing for identifying high viral load samples. Broadening the reportable range of values may generate even better performance.


Subject(s)
COVID-19 , SARS-CoV-2 , Female , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , COVID-19/diagnosis , Immunologic Tests , Area Under Curve , Immunoassay , Sensitivity and Specificity
7.
J Clin Lab Anal ; 37(6): e24867, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2276343

ABSTRACT

INTRODUCTION: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is one of the current public health care challenges. The main strategy adopted to prevent the spread of infection is the rapid identification of COVID-19-positive subjects. The aim of this study was to compare the performance of Lumipulse® antigen immunoassay with the real-time RT-PCR, the gold standard for the diagnosis of SARS-CoV-2 infection, in a strictly selected asymptomatic population. MATERIALS AND METHODS: A total of 392 consecutive oro-nasopharyngeal swabs were collected from patients with no symptoms related to COVID-19 at the Emergency Department of AORN Sant'Anna e San Sebastiano, Caserta, Italy to evaluate the analytical performance of Lumipulse® SARS-CoV-2 antigen compared to qualitative real-time RT-PCR in asymptomatic patients. RESULTS: Lumipulse® SARS-CoV-2 antigen assay shows an overall agreement rate of 97% with a sensitivity of 96% and a specificity of 98%, with a PPV and NPV of 97%. The sensitivity varies according to the cycle threshold (Ct )-value reaching 100% and 86% with 15 < Ct < 25 and Ct ≥ 25, respectively. The ROC analysis yielded an AUC value of 0.98, suggesting that the antigen test may accurately detect SARS-CoV-2. CONCLUSION: Our data showed that Lumipulse® SARS-CoV-2 antigen assay might be an efficient tool in the identification and limitation of SARS-CoV-2 transmission in large asymptomatic populations.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/epidemiology , Immunologic Tests , Emergency Service, Hospital , ROC Curve , Sensitivity and Specificity
8.
Clin Lab ; 69(3)2023 Mar 01.
Article in English | MEDLINE | ID: covidwho-2275671

ABSTRACT

BACKGROUND: This study aimed to assess clinical performance of a rapid antigen test (RAT) for screening asymptomatic patients during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) omicron outbreak. METHODS: RAT with the routine real-time reverse transcription-polymerase chain reaction (rRT-PCR) using the same nasopharyngeal swab in universal transport medium was performed for rapid screening of asymptomatic caregivers of emergent patients from March to April 2022 in a tertiary-care hospital in Korea. Clinical performance of RAT compared to that analyzed by rRT-PCR was evaluated. RESULTS: A total of 900 caregivers were enrolled in this study, of which 14 (1.6%) were RAT-positive and 44 (5.0%) were positive for rRT-PCR. Overall sensitivity and specificity of RAT were 31.8% and 100.0%, respectively. CONCLUSIONS: Caution must be taken when using RAT as a screening test for asymptomatic caregivers as this may lead to outbreaks among high-risk patients.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Caregivers , COVID-19 Testing , Immunologic Tests , Sensitivity and Specificity
9.
Methods Mol Biol ; 2612: 195-224, 2023.
Article in English | MEDLINE | ID: covidwho-2253002

ABSTRACT

Traditional immunoassays to detect secreted or intracellular proteins can be tedious, require multiple washing steps, and are not easily adaptable to a high-throughput screening (HTS) format. To overcome these limitations, we developed Lumit, a novel immunoassay approach that combines bioluminescent enzyme subunit complementation technology and immunodetection. This bioluminescent immunoassay does not require washes or liquid transfers and takes less than 2 h to complete in a homogeneous "Add and Read" format. In this chapter, we describe step-by-step protocols to create Lumit immunoassays for the detection of (1) secreted cytokines from cells, (2) phosphorylation levels of a specific signaling pathway node protein, and (3) a biochemical protein-protein interaction between a viral surface protein and its human receptor.


Subject(s)
Cytokines , Immunologic Tests , Humans , Immunoassay/methods
10.
J Clin Virol ; 161: 105419, 2023 04.
Article in English | MEDLINE | ID: covidwho-2251532

ABSTRACT

BACKGROUND: A SARS-CoV-2+Flu A/B+RSV Combo Rapid test may be more relevant than Rapid Antigen Diagnostic (RAD) tests targeting only SARS-CoV-2 since we are facing a concurrent circulation of these viruses during the winter season. OBJECTIVES: To assess the clinical performance of a SARS-CoV-2+Flu A/B+RSV Combo test in comparison to a multiplex RT-qPCR. STUDY DESIGN: Residual nasopharyngeal swabs issued from 178 patients were included. All patients, adults and children, were symptomatic and presented at the emergency department with flu-like symptoms. Characterization of the infectious viral agent was done by RT-qPCR. The viral load was expressed as cycle threshold (Ct). Samples were then tested using the multiplex RAD test Fluorecare®à¸ SARS-CoV-2 & Influenza A/B & RSV Antigen Combo Test. Data analysis was carried out using descriptive statistics. RESULTS: The sensitivity of the test varies according to the virus, with the highest sensitivity observed for Influenza A (80.8.% [95%CI: 67.2 - 94.4]) and the lowest sensitivity observed for RSV (41.5% [95%CI: 26.2 - 56.8]). Higher sensitivities were observed for samples with high viral loads (Ct < 20) and decrease with low viral loads. The specificity for SARS-CoV-2, RSV and Influenza A and B was >95%. CONCLUSIONS: The Fluorecare® combo antigenic presents satisfying performance in real-life clinical setting for Influenza A and B in samples with high viral load. This could be useful to allow a rapid (self-)isolation as the transmissibility of these viruses increase with the viral load. According to our results, its use to rule-out SARS-CoV-2 and RSV infection is not sufficient.


Subject(s)
COVID-19 , Influenza, Human , Respiratory Syncytial Virus Infections , Adult , Child , Humans , Influenza, Human/diagnosis , SARS-CoV-2 , COVID-19/diagnosis , Respiratory Syncytial Virus Infections/diagnosis , Immunologic Tests , Sensitivity and Specificity
11.
PLoS One ; 18(3): e0283576, 2023.
Article in English | MEDLINE | ID: covidwho-2280237

ABSTRACT

COVID-19 oral treatments require initiation within 5 days of symptom onset. Although antigen tests are less sensitive than RT-PCR, rapid results could facilitate entry to treatment. We collected anterior nasal swabs for BinaxNOW and RT-PCR testing and clinical data at a walk-up, community site in San Francisco, California between January and June 2022. SARS-CoV-2 genomic sequences were generated from positive samples and classified according to subtype and variant. Monte Carlo simulations were conducted to estimate the expected proportion of SARS-CoV-2 infected persons who would have been diagnosed within 5 days of symptom onset using RT-PCR versus BinaxNOW testing. Among 25,309 persons tested with BinaxNOW, 2,799 had concomitant RT-PCR. 1137/2799 (40.6%) were SARS-CoV-2 RT-PCR positive. We identified waves of predominant omicron BA.1, BA.2, BA.2.12, BA.4, and BA.5 among 720 sequenced samples. Among 1,137 RT-PCR positive samples, 788/1137 (69%) were detected by BinaxNOW; 94% (669/711) of those with Ct value <30 were detected by BinaxNOW. BinaxNOW detection was consistent over lineages. In analyses to evaluate entry to treatment, BinaxNOW detected 81.7% (361/442, 95% CI: 77-85%) of persons with COVID-19 within 5 days of symptom onset. In comparison, RT-PCR (24-hour turnaround) detected 84.2% (372/442, 95% CI: 80-87%) and RT-PCR (48-hour turnaround) detected 67.0% (296/442, 95% CI: 62-71%) of persons with COVID-19 within 5 days of symptom onset. BinaxNOW detected high viral load from anterior nasal swabs consistently across omicron sublineages emerging between January and June of 2022. Simulations support BinaxNOW as an entry point for COVID-19 treatment in a community field setting.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , COVID-19/epidemiology , SARS-CoV-2/genetics , San Francisco/epidemiology , COVID-19 Drug Treatment , Immunologic Tests , Sensitivity and Specificity
12.
Travel Med Infect Dis ; 52: 102548, 2023.
Article in English | MEDLINE | ID: covidwho-2237128

ABSTRACT

BACKGROUND: We aim to determine if nasal samples have equivalent detection sensitivity to nasopharyngeal swabs for RAT and evaluate the diagnostic accuracy of nasal swabs with RAT. METHODS: PubMed and Web of Science were searched for eligible studies published before August 23, 2022. A bivariate random effects model was used to perform the quantitative synthesis. RESULTS: The pooled sensitivity, pooled specificity, positive likelihood ratio, negative likelihood ratio, and summary AUC on nasal swabs with RAT were 0.81 (95% CI, 0.77-0.85), 1.00 (95% CI: 0.99-1.00), 0.97 (95% CI, 0.95-0.98), 298.91 (95% CI, 144.71-617.42) and 0.19 (95% CI, 0.15-0.23), respectively. WHO required RAT kits to perform with a sensitivity of 0.80 and a specificity of 0.97, nasal swabs (0.81) achieved the required sensitivity while nasopharyngeal swabs (0.75) did not. The symptomatic population yielded higher pooled sensitivity than the asymptomatic population (0.86 versus 0.71), with a pooled sensitivity of 0.90 for five days of symptom onset. CONCLUSION: Nasal sampling had a great performance and yielded a high sensitivity in detecting SARS-CoV-2 using RAT, we believe that RAT performed with nasal swabs is a good alternative for detecting SARS-CoV-2, especially early in the onset of symptoms.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Immunologic Tests , Nose
13.
Front Immunol ; 13: 1016991, 2022.
Article in English | MEDLINE | ID: covidwho-2224771

ABSTRACT

Interleukin-26 (IL-26) is released by several immune and structural cells following stimulation of toll-like receptors (TLRs), whereupon it can directly inhibit viral replication and enhance neutrophil chemotaxis. Given these unique properties, IL-26 has emerged as an intriguing mediator of host defense in the lungs. However, the role of IL-26 in COVID-19 has not been thoroughly investigated. Here, we characterized the involvement of IL-26 in the hyperinflammation and tissue damage that occurs in patients with acute COVID-19. We found that IL-26 is markedly increased in blood samples from these patients, and that the concentration of IL-26 correlates with those of the neutrophil-mobilizing cytokines IL-8 and TNFα, respectively. Moreover, the increase in blood IL-26 correlates with enhanced surface expression of the "don't eat me" signal CD47 on blood neutrophils isolated from patients with acute COVID-19. Finally, we found that the blood concentration of IL-26 correlates with that of increased lactate dehydrogenase, an established marker of tissue damage, and decreased mean corpuscular hemoglobin (MCH), a previously verified hematological aberration in COVID-19, both of which are associated with severe disease. Thus, our findings indicate that increased systemic IL-26 associates with markers of hyperinflammation and tissue damage in patients with acute COVID-19, thereby forwarding the kinocidin IL-26 as a potential target for diagnosis, monitoring, and therapy in this deadly disease.


Subject(s)
COVID-19 , Humans , Research Personnel , Immunologic Tests , Biomarkers , Neutrophils
14.
Virol J ; 19(1): 202, 2022 Dec 01.
Article in English | MEDLINE | ID: covidwho-2153609

ABSTRACT

BACKGROUND: The objective of our investigation was to better understand barriers to implementation of self-administered antigen screening testing for SARS-CoV-2 at institutions of higher education (IHE). METHODS: Using the Quidel QuickVue At-Home COVID-19 Test, 1347 IHE students and staff were asked to test twice weekly for seven weeks. We assessed seroconversion using baseline and endline serum specimens. Online surveys assessed acceptability. RESULTS: Participants reported 9971 self-administered antigen test results. Among participants who were not antibody positive at baseline, the median number of tests reported was eight. Among 324 participants seronegative at baseline, with endline antibody results and ≥ 1 self-administered antigen test results, there were five COVID-19 infections; only one was detected by self-administered antigen test (sensitivity = 20%). Acceptability of self-administered antigen tests was high. CONCLUSIONS: Twice-weekly serial self-administered antigen testing in a low prevalence period had low utility in this investigation. Issues of testing fatigue will be important to address in future testing strategies.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Students , Immunologic Tests , Seroconversion
15.
Clin Lab Med ; 42(2): 203-222, 2022 06.
Article in English | MEDLINE | ID: covidwho-2130437

ABSTRACT

Though rapid antigen tests have historically problematic performance characteristics for the diagnosis of respiratory viral infections such as influenza, they have attained an unprecedented level of use in the context of the COVID-19 pandemic. Ease of use and scalability of rapid antigen tests has facilitated a democratization and scale of testing beyond anything reasonably achievable by traditional laboratory-based testing. In this chapter, we discuss the performance characteristics of rapid antigen testing for SARS-CoV-2 detection and their application to non-traditional uses beyond clinical diagnostic testing.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Immunologic Tests , Pandemics
16.
PLoS One ; 17(11): e0273107, 2022.
Article in English | MEDLINE | ID: covidwho-2140473

ABSTRACT

BACKGROUND: The global coronavirus disease 2019 (COVID-19) has presented significant challenges and created concerns worldwide. Besides, patients who have experienced a SARS-CoV-2 infection could present post-viral complications that can ultimately lead to pulmonary fibrosis. Serum levels of Krebs von den Lungen 6 (KL-6), high molecular weight human MUC1 mucin, are increased in the most patients with various interstitial lung damage. Since its production is raised during epithelial damages, KL-6 could be a helpful non-invasive marker to monitor COVID-19 infection and predict post-infection sequelae. METHODS: We retrospectively evaluated KL-6 levels of 222 COVID-19 infected patients and 70 healthy control. Serum KL-6, fibrinogen, lactate dehydrogenase (LDH), platelet-lymphocytes ratio (PLR) levels and other biological parameters were analyzed. This retrospective study also characterized the relationships between serum KL-6 levels and pulmonary function variables. RESULTS: Our results showed that serum KL-6 levels in COVID-19 patients were increased compared to healthy subjects (470 U/ml vs 254 U/ml, P <0.00001). ROC curve analysis enabled us to identify that KL-6 > 453.5 U/ml was associated with COVID-19 (AUC = 0.8415, P < 0.0001). KL-6 level was positively correlated with other indicators of disease severity such as fibrinogen level (r = 0.1475, P = 0.0287), LDH level (r = 0,31, P = 0,004) and PLR level (r = 0.23, P = 0.0005). However, KL-6 levels were not correlated with pulmonary function tests (r = 0.04, P = 0.69). CONCLUSIONS: KL-6 expression was correlated with several disease severity indicators. However, the association between mortality and long-term follow-up outcomes needs further investigation. More extensive trials are required to prove that KL-6 could be a marker of disease severity in COVID-19 infection.


Subject(s)
COVID-19 , Humans , Fibrinogen , Immunologic Tests , Retrospective Studies , SARS-CoV-2
18.
Sensors (Basel) ; 22(19)2022 Sep 28.
Article in English | MEDLINE | ID: covidwho-2066350

ABSTRACT

Due to the recent pandemic caused by coronavirus disease 2019 (COVID-19), the lateral flow immunoassay used for its rapid antigen test is more popular than ever before. However, the history of the lateral flow immunoassay is about 60 years old, and its original purpose of use, such as a COVID-19 rapid antigen test or a pregnancy test, was the qualitative detection of a target analyte. Recently, the demand for quantitative analysis of lateral flow immunoassays is increasing in various fields. Lateral flow immunoassays for quantitative detection using various materials and sensor technologies are being introduced, and readers for analyzing them are being developed. Quantitative analysis readers are highly anticipated for their future development in line with technological advancements such as optical, magnetic field, photothermal, and electrochemical sensors and trends such as weight reduction, miniaturization, and cost reduction of systems. In addition, the sensing, processing, and communication functions of portable personal devices such as smartphones can be used as tools for the quantitative analysis of lateral flow immunoassays. As a result, lateral flow immunoassays can efficiently achieve the goal of rapid diagnosis by point-of-care testing. Readers used for the quantification of lateral flow immunoassays were classified according to the adopted sensor technology, and the research trends in each were reviewed in this paper. The development of a quantitative analysis system was often carried out in the assay aspect, so not only the readers but also the assay development cases were reviewed if necessary. In addition, systems for quantitative analysis of COVID-19, which have recently been gaining importance, were introduced as a separate section.


Subject(s)
COVID-19 , COVID-19/diagnosis , Humans , Immunoassay/methods , Immunologic Tests , Middle Aged , Miniaturization , Point-of-Care Systems , Point-of-Care Testing
19.
J Infect Dis ; 226(11): 1903-1908, 2022 Nov 28.
Article in English | MEDLINE | ID: covidwho-1997060

ABSTRACT

In this population-based cohort of 7538 adults, combined immunoglobulin (Ig) G, IgA, and IgM (IgG/A/M) anti-spike titers measured after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination were predictive of protection against breakthrough SARS-CoV-2 infection. Discrimination was significantly improved by adjustment for factors influencing risk of SARS-CoV-2 exposure, including household overcrowding, public transport use, and visits to indoor public places. Anti-spike IgG/A/M titers showed positive correlation with neutralizing antibody titers (rs = 0.80 [95% confidence interval, .72-.86]; P < .001) and S peptide-stimulated interferon-γ concentrations (rs = 0.31 [.13-.47]; P < .001).


Subject(s)
COVID-19 , Adult , Humans , COVID-19/prevention & control , SARS-CoV-2 , Longitudinal Studies , Immunologic Tests , Immunoglobulin G , Antibodies, Viral
20.
J Med Virol ; 94(10): 5033-5037, 2022 10.
Article in English | MEDLINE | ID: covidwho-1981839

ABSTRACT

The severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) Omicron was classified as a variant of concern in November 2021. The sublineage BA.2 spreads rapidly worldwide. Currently, there is a lack of data for the parallel comparison of Rapid Antigen Test (RAT) Kits to detect SARS-CoV-2 Omicron BA.2. We evaluated the analytical sensitivity of 12 RAT kits to detect Omicron BA.2 in the present study. Analytical sensitivity was determined by means of the limit of detection (LOD). We prepared a dilution set using a respiratory specimen collected from a COVID-19 patient infected by Omicron BA.2. The reverse transcription-polymerase chain reaction was used as a reference method. The LOD results showed that all 12 RAT kits had comparable analytical sensitivity to detect Omicron BA.2. The RAT kits selected in the current study may be used for the first-line screening of the rapid spreading Omicron BA.2.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Immunologic Tests , RNA, Viral/analysis , SARS-CoV-2/genetics
SELECTION OF CITATIONS
SEARCH DETAIL